We use cookies and tracking technologies to improve your experience and analyze site usage. Some information may be shared with third parties for analytics and advertising. You can accept all cookies or decline non-essential tracking. To find out more about the cookies we use, see our Privacy policy.
The NEMA 4X Enclosed Motor Starter is a reliable and versatile solution for controlling and protecting industrial motors. Suitable for a wide range of applications, including manufacturing, processing, and material handling, this starter provides a secure and efficient way to start and stop motors. With its separate control voltage and remote start terminals, it offers flexibility and convenience. The starter's 24-60V AC/DC coil and 24-29A overload protection ensure safe and reliable operation. Its rugged NEMA 4X enclosure protects against harsh environments, making it ideal for use in challenging industrial settings.
Top product features:
38A 3 phase capability
Reset button for remote start and reset
24-60V AC/DC coil for versatile control power options
Top product applications:
Industrial automation: This product is suitable for use in industrial settings where a reliable and compact motor starter is required to control and protect 3-phase motors.
HVAC systems: The NEMA 4X rating and remote start reset button make this product an ideal choice for use in harsh environments such as HVAC systems, where the motor starter needs to be protected from dust, water, and other contaminants.
Water treatment plants: The separate control voltage and remote start terminals feature of this product makes it suitable for use in water treatment plants where the motor starter needs to be controlled and protected from external sources, such as a separate control panel or a remote switch.
Springer controls manufactures a complete line of iec enclosed ac motor starters up to 60hp or 80a. Assembled motor starters consist of a contactor overload relay and a nema 4x rated polycarbonate enclosure. To select the proper starter for your requirements 1) refer to the motor or equipment nameplate to verify the full load amperage (fla) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (amps) higher than the fla of your motor. 2) choose the control power used to close the contactor. 3) choose the overload by selecting a current range that contains the fla of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria 4) incoming power if the line power will be used as the control power as well this is referred to as a "direct-online starter" if the control voltage is not the same as the line voltage we refer to this as "separate control voltage" if the starter needs to be activated from an external switch we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" it is assumed in this arrangement that the line voltage and control voltage are the sameif you would like remote start terminals and will be using different voltage for line power and control power we refer to this as "separate control voltage + remote start terminals" features ul style"margin-top0px; padding-top 5px; padding-bottom 5px;" 38a 3 phase separate control voltage + remote start terminals reset button only 24-60v ac/dc coil 24-29a o/l nema 4x poly