We use cookies and tracking technologies to improve your experience and analyze site usage. Some information may be shared with third parties for analytics and advertising. You can accept all cookies or decline non-essential tracking. To find out more about the cookies we use, see our Privacy policy.
The NEMA 4X Enclosed Motor Starter from Springer Controls is a versatile and reliable solution for controlling AC motors in harsh environments. Ideal for use in industrial settings, this starter features a separate coil voltage start/stop function, allowing for precise control of motor operation. With a wide range of voltage and current options, it can be tailored to meet the specific needs of your application. Suitable for use with 3-phase power, it's perfect for controlling motors in factories, warehouses, and other industrial facilities where reliability and durability are paramount.
Top product features:
12A 3 phase separate coil voltage start/stop
250-500V AC/DC coil
5.7-7.6A overload protection
Top product applications:
Industrial Automation: The NEMA 4X Enclosed Motor Starter is suitable for use in industrial automation applications, such as controlling the operation of conveyor belts, pumps, and other machinery.
HVAC Systems: This motor starter can be used in HVAC systems to control the operation of fans, compressors, and other equipment, providing a reliable and efficient means of controlling motor operation.
Pumps and Water Treatment: The NEMA 4X Enclosed Motor Starter is also suitable for use in pumps and water treatment applications, such as controlling the operation of submersible pumps, centrifugal pumps, and other equipment.
Springer controls manufactures a complete line of iec enclosed ac motor starters up to 60hp or 80a. Assembled motor starters consist of a contactor overload relay and a nema 4x rated polycarbonate enclosure. To select the proper starter for your requirements 1) refer to the motor or equipment nameplate to verify the full load amperage (fla) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (amps) higher than the fla of your motor. 2) choose the control power used to close the contactor. 3) choose the overload by selecting a current range that contains the fla of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria 4) incoming power if the line power will be used as the control power as well this is referred to as a "direct-online starter" if the control voltage is not the same as the line voltage we refer to this as "separate control voltage" if the starter needs to be activated from an external switch we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" it is assumed in this arrangement that the line voltage and control voltage are the sameif you would like remote start terminals and will be using different voltage for line power and control power we refer to this as "separate control voltage + remote start terminals" features ul style"margin-top0px; padding-top 5px; padding-bottom 5px;" 12a 3 phase separate coil voltage start/stop 250-500v ac/dc coil 5.7-7.6a o/l nema 4x poly