We use cookies and tracking technologies to improve your experience and analyze site usage. Some information may be shared with third parties for analytics and advertising. You can accept all cookies or decline non-essential tracking. To find out more about the cookies we use, see our Privacy policy.
The Springer Controls AF0906R2G-1B is a versatile and reliable NEMA 4X Enclosed Motor Starter suitable for a wide range of applications. This 9A, 3-phase starter is designed for use in harsh environments and features a reset button for easy operation. With a 24-60V AC/DC coil and 2.3-3.1A overload protection, it provides reliable control and protection for motors up to 60HP or 80A. Ideal for industrial and commercial settings, this starter is perfect for applications such as pumps, fans, and conveyors, offering a cost-effective and efficient solution for motor control and protection.
Top product features:
9A 3 phase capability
Separate control voltage for flexibility in setup
Reset button for easy restart
Top product applications:
Industrial Automation and Control Systems
Motor Control Panels for Pump and Fan Applications
Springer controls manufactures a complete line of iec enclosed ac motor starters up to 60hp or 80a. Assembled motor starters consist of a contactor overload relay and a nema 4x rated polycarbonate enclosure. To select the proper starter for your requirements 1) refer to the motor or equipment nameplate to verify the full load amperage (fla) at the input voltage you will supply. Be sure to confirm whether it is 1phase or 3phase power to the motor. Choose a starter rated for current (amps) higher than the fla of your motor. 2) choose the control power used to close the contactor. 3) choose the overload by selecting a current range that contains the fla of the motor from step 1. Once you have done this it should narrow down the starters to only options suitable for your motor and power requirements. Then select your starter based on the following optional criteria 4) incoming power if the line power will be used as the control power as well this is referred to as a "direct-online starter" if the control voltage is not the same as the line voltage we refer to this as "separate control voltage" if the starter needs to be activated from an external switch we add terminals to accept the control power input from that switch. We refer to this as "remote start terminals" it is assumed in this arrangement that the line voltage and control voltage are the sameif you would like remote start terminals and will be using different voltage for line power and control power we refer to this as "separate control voltage + remote start terminals" features ul style"margin-top0px; padding-top 5px; padding-bottom 5px;" 9a 3 phase separate control voltage reset button only 24-60v ac/dc coil 2.3-3.1a o/l nema 4x poly