We use cookies and tracking technologies to improve your experience and analyze site usage. Some information may be shared with third parties for analytics and advertising. You can accept all cookies or decline non-essential tracking. To find out more about the cookies we use, see our Privacy policy.
The Edwards Signaling FSRZI-SA Remote Zone Indicator is a versatile solution for common system annunciation and zone status indication. Ideal for use in commercial and industrial settings, this remote indicator features four LEDs that display power status, alarm, supervisory, trouble, and ground fault conditions. A local silence/lamp test switch allows for easy troubleshooting and testing. The device is part of the e-fsc series, offering a range of remote annunciation options. Perfect for applications where multiple indicators are required, this unit can be mounted in a standard electrical box with up to two additional modules, making it a reliable and efficient choice.
Top product features:
The serial remote annunciator bus can be run up to 700 feet on untwisted non-shielded 18-gauge cable.
The remote system indicator includes four LEDs that indicate power status, alarm, supervisory, trouble, and ground fault.
The remote zone indicator contains five red LEDs that indicate zone status, with jumper settings allowing for selection of either IDCs 1-5 or IDCs 6-7.
Top product applications:
Common system annunciation
Zone status indication
Power status, alarm, supervisory trouble, and ground fault indication
The edwards e-fsc series panels have several remote annunciation options. The serial remote annunciator bus can be run up to 700 feet on untwisted non-shielded 18-gauge cable. Several annunciator models round out the family to provide a range of features and functions. As many as three annunciators may be mounted in a single standard electrical box sharing an attractive trim plate that blends with any decor. The fsrsi remote system indicator is ideal for common system annunciation. It includes four leds and a local silence/lamp test switch. The leds indicate power status alarm supervisory trouble and ground fault. The silence switch will silence the onboard trouble buzzer if active. The switch can also be used to initiate a lamp test of the leds on all connected fsrsis and fsrzis. The fsrzi remote zone indicator is used to indicate zone status. It contains five red leds. Depending on the jumper setting selected the leds will indicate either idcs 1 through 5 or idcs 6 through 7. The panel can support two modules programmed for each selection.