The store will not work correctly when cookies are disabled.
We use cookies and tracking technologies to improve your experience and analyze site usage. Some information may be shared with third parties for analytics and advertising. You can accept all cookies or decline non-essential tracking. To find out more about the cookies we use, see our Privacy policy.
The Kuriyama Fire Products JAFLINE HD Double Jacket Fire Hose is a superior fire attack hose designed for use in a variety of applications, including fire suppression and rescue operations. Its lightweight and flexible design allows for easier storage and handling, making it ideal for emergency response situations. Meets or exceeds NFPA 1961 fire hose standard and NSF 61 potable water standard, ensuring safe and reliable performance. Suitable for use in a range of environments, including industrial, commercial, and residential settings, this hose is a reliable choice for fire departments and emergency responders.
Top product features:
The Jafline HD Double Jacket Fire Hose is made of all-synthetic fibers, making it much lighter in weight and more flexible than cotton-synthetic hose, allowing for greater storage capacity in a given space.
The outer jacket is thoroughly impregnated with a polymer compound that provides superior resistance to chemicals, abrasion, and ultraviolet light.
The thermoplastic lining is unaffected by ozone, has a smooth finish, and meets or exceeds the NFPA 1961 fire hose standard 2013 edition.
Armored textiles n52h15hdw50n jafline hd double jacket fire hose 1-1/2" x 50 ft 400 psi white jafline is a superior double jacket polyurethane-lined highly durable and lightweight fire attack hose. It meets or exceeds nfpa 1961 fire hose standard 2013 edition. Potable water standard nsf 61 the jafline product contains material approved by the national sanitation foundation under standard 61"listed drinking water system components-health effects potable water material." . Jacket construction the warp and weft for the outer and inner jackets is virgin spun polyester yarn. Hose comprised of all-synthetic fibers is much lighter in weight and more flexible than cotton-synthetic hose; therefore a greater amount can be stored in a given space. The outer jacket is thoroughly impregnated with a polymer compound to provide superior resistance to chemicals abrasion and ultraviolet light. Compound is heat set at 275°f. The jackets must fit snugly inside one another under zero pressure or under proof and service test pressures. Lining the thermoplastic lining shall be a single-ply extruded tube and shall be unaffected by ozone. The finished form shall be free of pits or other imperfections and shall have a smooth finish. No reclaimed material shall be used. Thickness of the liner shall be .015 to .018 for 1" 1-1/2" and 1-3/4" and .022" to .025 for the 2-1/2" hose. Shore hardness shall be 40 5 durometer on the "d" scale. The tensile strength of the liner shall not be less than 3000 psi with a minimum elongation of 400. Adhesion the adhesion between the liner and the inside jacket is such that the rate of separation of a 1.5" wide strip cut transversely shall not be greater than 1" per minute over a period of ten minutes under a weight of 15 pounds. Accelerated aging lining specimens subjected to an exposure of 158°+/- 3.6°for a duration of 96hours shall be conditioned to astm d 573 and astm d4112 standard test methods for vulcani